CVE Vulnerabilities

CVE-2014-9197

Improper Access Control

Published: Jan 27, 2015 | Modified: Jan 28, 2015
CVSS 3.x
N/A
Source:
NVD
CVSS 2.x
7.8 HIGH
AV:N/AC:L/Au:N/C:C/I:N/A:N
RedHat/V2
RedHat/V3
Ubuntu

The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.

Weakness

The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

Affected Software

Name Vendor Start Version End Version
Etg3000_factorycast_hmi_gateway_firmware Schneider-electric 1.60.2 (including) 1.60.2 (including)

Extended Description

Access control involves the use of several protection mechanisms such as:

When any mechanism is not applied or otherwise fails, attackers can compromise the security of the product by gaining privileges, reading sensitive information, executing commands, evading detection, etc. There are two distinct behaviors that can introduce access control weaknesses:

Potential Mitigations

  • Compartmentalize the system to have “safe” areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area.
  • Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.

References