CVE Vulnerabilities

CVE-2017-6866

Improper Access Control

Published: Aug 07, 2017 | Modified: Nov 21, 2024
CVSS 3.x
6.5
MEDIUM
Source:
NVD
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
CVSS 2.x
4 MEDIUM
AV:N/AC:L/Au:S/C:P/I:N/A:N
RedHat/V2
RedHat/V3
Ubuntu

A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated low-privileged remote user to gain read access to data in the XHQ solution exceeding his configured permission level.

Weakness

The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

Affected Software

Name Vendor Start Version End Version
Xhq_server Siemens * 4.7.1.2 (including)
Xhq_server Siemens * 5.0.0.1 (including)

Extended Description

Access control involves the use of several protection mechanisms such as:

When any mechanism is not applied or otherwise fails, attackers can compromise the security of the product by gaining privileges, reading sensitive information, executing commands, evading detection, etc. There are two distinct behaviors that can introduce access control weaknesses:

Potential Mitigations

  • Compartmentalize the system to have “safe” areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area.
  • Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.

References