A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.
The product does not properly control the allocation and maintenance of a limited resource.
Name | Vendor | Start Version | End Version |
---|---|---|---|
Scalance_s602_firmware | Siemens | 3.0 (including) | 4.1 (excluding) |
Mitigation of resource exhaustion attacks requires that the target system either:
The first of these solutions is an issue in itself though, since it may allow attackers to prevent the use of the system by a particular valid user. If the attacker impersonates the valid user, they may be able to prevent the user from accessing the server in question.
The second solution is simply difficult to effectively institute – and even when properly done, it does not provide a full solution. It simply makes the attack require more resources on the part of the attacker.