The Bluetooth Low Energy Secure Manager Protocol (SMP) implementation in Texas Instruments SimpleLink SIMPLELINK-CC2640R2-SDK through 2.2.3 allows the Diffie-Hellman check during the Secure Connection pairing to be skipped if the Link Layer encryption setup is performed earlier. An attacker in radio range can achieve arbitrary read/write access to protected GATT service data, cause a denial of service, or possibly control a devices function by establishing an encrypted session with an unauthenticated Long Term Key (LTK).
The product does not verify, or incorrectly verifies, the cryptographic signature for data.
Name | Vendor | Start Version | End Version |
---|---|---|---|
Simplelink-cc2640r2_software_development_kit | Ti | * | 2.2.3 (including) |