CVE Vulnerabilities

CVE-2020-28212

Improper Restriction of Excessive Authentication Attempts

Published: Nov 19, 2020 | Modified: Jan 31, 2022
CVSS 3.x
9.8
CRITICAL
Source:
NVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.x
7.5 HIGH
AV:N/AC:L/Au:N/C:P/I:P/A:P
RedHat/V2
RedHat/V3
Ubuntu

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when a brute force attack is done over Modbus.

Weakness

The product does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it more susceptible to brute force attacks.

Affected Software

Name Vendor Start Version End Version
Ecostruxure_control_expert Schneider-electric * *

Potential Mitigations

  • Common protection mechanisms include:

  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid.

  • Consider using libraries with authentication capabilities such as OpenSSL or the ESAPI Authenticator. [REF-45]

References