CVE Vulnerabilities

CVE-2020-5807

Improper Handling of Exceptional Conditions

Published: Dec 29, 2020 | Modified: Dec 30, 2020
CVSS 3.x
7.5
HIGH
Source:
NVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS 2.x
5 MEDIUM
AV:N/AC:L/Au:N/C:N/I:N/A:P
RedHat/V2
RedHat/V3
Ubuntu

An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected.

Weakness

The product does not handle or incorrectly handles an exceptional condition.

Affected Software

Name Vendor Start Version End Version
Factorytalk_diagnostics Rockwellautomation * 6.11 (including)