CVE Vulnerabilities

CVE-2021-32984

Authentication Bypass Using an Alternate Path or Channel

Published: Apr 04, 2022 | Modified: Nov 21, 2024
CVSS 3.x
9.8
CRITICAL
Source:
NVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.x
7.5 HIGH
AV:N/AC:L/Au:N/C:P/I:P/A:P
RedHat/V2
RedHat/V3
Ubuntu

All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project without authorization.

Weakness

The product requires authentication, but the product has an alternate path or channel that does not require authentication.

Affected Software

Name Vendor Start Version End Version
C0-10dd1e-d_firmware Automationdirect * 3.00 (excluding)

Potential Mitigations

References