CVE Vulnerabilities

CVE-2022-21770

Improper Link Resolution Before File Access ('Link Following')

Published: Jul 06, 2022 | Modified: Jul 14, 2022
CVSS 3.x
6.7
MEDIUM
Source:
NVD
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CVSS 2.x
4.6 MEDIUM
AV:L/AC:L/Au:N/C:P/I:P/A:P
RedHat/V2
RedHat/V3
Ubuntu

In sound driver, there is a possible information disclosure due to symlink following. This could lead to local information disclosure with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06558663; Issue ID: ALPS06558663.

Weakness

The product attempts to access a file based on the filename, but it does not properly prevent that filename from identifying a link or shortcut that resolves to an unintended resource.

Affected Software

Name Vendor Start Version End Version
Android Google 11.0 11.0
Android Google 12.0 12.0

Potential Mitigations

  • Follow the principle of least privilege when assigning access rights to entities in a software system.
  • Denying access to a file can prevent an attacker from replacing that file with a link to a sensitive file. Ensure good compartmentalization in the system to provide protected areas that can be trusted.

References